ORIENTAL MOTOR CO., LTD.

EC Fans EMU Series

EMU1238M-2

EMU1238M-2

Fan

Product Classification Product Name List Price List Price Shipping Date
Fan EMU1238M-2 SGD 106 USD 85 11 Working Days

Included

  • Fan, Plug Cord for Power Supply (2 m, Product Name : PCA2B2), Alarm Cable (2 m), Operating Manual

Specifications

Characteristics

Air Flow - Static Pressure Characteristics

Air Flow - Static Pressure Characteristics

Dimensions

Dimensions (Body)

Dimensions (Body)

Panel Cut-Out

Panel Cut-Out

Data Download

Other Specifications

General Specifications

Item EMU938, EMU1238 EMU1225
Insulation Resistance After continuous operation at normal ambient temperature and humidity, the measurement value between the input terminal and the frame is 100 MΩ min. using a 500 VDC megger.
 
 
After continuous operation at normal ambient temperature and humidity, the measurement value between the lead wire and the frame is 100 MΩ min. using a 500 VDC megger.
 
 
Dielectric Strength No abnormality is observed even with an application of 1.5 kVAC at 50 Hz between the input terminal and the frame for 1 minute after continuous operation at normal ambient temperature and humidity.
 
 
No abnormality is observed even with an application of 2.5 kVAC at 50 Hz between the lead wire and the frame for 1 minute after continuous operation at normal ambient temperature and humidity.
 
 

For the alarm type only, no abnormality is observed even with an application of 1.5 kVAC at 50 Hz between the power-supply lead wire and the alarm lead wire for 1 minute after continuous operation at normal ambient temperature and humidity.
 
 
Temperature Rise After continuous operation at normal ambient temperature and humidity at maximum air flow, when temperature becomes constant, the measurement value of the winding temperature rise using the thermometer method is 30 °C max.
 
 
After continuous operation at normal ambient temperature and humidity at maximum air flow, when temperature becomes constant, the measurement value of the winding temperature rise using the thermometer method is 35 °C max.
 
 
Thermal Class UL/CSA Standards: 105 (A)
EN Standards: 120 (E)
Electrical Appliance and Material Safety Act: 120 (E)
UL/CSA Standards: 105 (A)
EN Standards: 120 (E)
Overheat Protection Built-in burnout prevention circuit
Operating Environment∗1 Ambient Temperature∗2 -20 to +75 °C -20 to +70 °C
Ambient Humidity 20 to 85 % (Non-condensing) 20 to 85 % (Non-condensing)
Storage Conditions∗1∗3 Ambient Temperature∗2 -30 to +75 °C -30 to +70 °C
Ambient Humidity 20 to 85 % (Non-condensing) 20 to 85 % (Non-condensing)
    ∗1 The operating environment and storage condition assumes conditions of being free from condensation, freezing, and vibration other than that of the fan, and external force.
    ∗2 Cannot be used in a temperature-controlled environment at -10 °C max., such as in a freezer.
    ∗3 The value for storage condition applies to short periods such as the period during transport.

Low Speed Alarm Specifications

An alarm is output when the cooling fan speed drops to a specific level. The output method is electronic alarm type

Alarm Specifications

Alarm Activation Speed EMU938M, C-EMU938M: 2000±300 r/min
EMU1238M, C-EMU1238M: 1700±255 r/min
Output Mode Open-collector output
Output Condition During Normal Rotation: L level (Internal transistor ON)
During Alarm Output: H level (Internal transistor OFF)
Maximum Rating Maximum Applied Voltage: 30 VDC or less
Maximum Inflow Current: 10 mA or less
Output Saturation Voltage: 1.0 VDC or less
Delay Function Built-In Starting Delay Time: 10 sec. max.
(The alarm function starts monitoring within 10 seconds after powering on)

Alarm Output Circuit Connection Example

Alarm Output Circuit Connection Example

Standards

Regulations and Standards Materials

Documents about compliance with regulations and standards can be downloaded from the "Data Download" tab on the product details page.
(The types of files available for download vary by product.)

Explanations of the Global Laws, Regulations and Standards can be found here.

Information about our compliance with regulations and standards for each of our product series can be found here.

Hazardous Substances

The product does not contain any substances (10 substances) exceeding the regulation values of the RoHS Directive (2011/65/EU, 2015/863/EU).

System Configuration

System Configuration

Related Products

Thermostat for Fan

Products Features
AM2-XA1
AM2-XA1
Features

Automatically operates and stops fans in response to temperature changes in the equipment.
This helps improve the equipment's "environmental" performance in terms of energy savings, noise reduction, etc.

  • Setting temperature range 0~+60 °C (setting error ±5 °C)
  • Easy to set temperature with thumbwheel dial
  • Designed for optimal air flow circulation, enabling stable operation
  • Compact size
    Width 33 mm × Height 70 mm × Depth 42.5 mm
  • *For the number of applicable cooling fans that can be used, click here.
  •  

Note

  • Cannot be used with three-phase type fans.

Cables and Accessories

close