Brushless Motors BLA Series

BLA550CB-GV

BLA550CB-GV

Motor

  This product is currently no longer available for sale
Product Classification Product Name List Price List Price Shipping Date
Motor BLA550CB-GV SGD 623 USD 498 Discontinued Product
(31.3.2019 discontinued)
• This product is a motor only (component) of the combi geared motor (circuit-Integrated).

Specifications

Data Download

Other Specifications

Specifications

Item Specifications
Speed Setting Methods Digital Setting: Max. 2 speeds (setting by speed teaching is possible)
Acceleration Time and Deceleration Time 0.5~15 seconds
Input Signal Photocoupler Input Input Resistance: 680 Ω or 5.1 kΩ
Operated by internal power supply: 6.0 VDC
Connectable external DC power supply: 12 VDC-10% ~ 24 VDC+20% current 100 mA min.
Signals can be assigned to general-purpose inputs X0 and X1 as desired. [ ]: Factory setting
[FWD input], [REV input], stop mode selection input, speed setting selection input, alarm reset input, external stop signal input
Output Signals Open-Collector Output
External use conditions: Control voltage 4.5~30.0 VDC Current max. 40 mA Speed Output: min. 5 mA
Signals can be assigned to general-purpose output Y0 as desired [ ]: Factory setting
Output during motor operation, alarm output 2, warning output, [alarm output 1], speed output
Protective Function When the following protective functions are activated, the motor will stop spontaneously and an alarm code will be displayed: (External stop is an instantaneous stop.)
Overcurrent, main circuit overheat, overvoltage, undervoltage, sensor error, overload, over-speed, EEPROM error, initial sensor error, prevention of operation at power-on, external stop
Insulation Resistance After continuous operation at normal ambient temperature and humidity, the value measured with a 500 VDC megger between the motor winding and motor case, between the power supply input and protective earth terminal, and between the power supply input and I/O terminal is 100 MΩ min.
Dielectric Strength After continuous operation at normal ambient temperature and humidity, no abnormality is observed when 50 Hz, 1.85 kVAC is applied between the motor winding and motor case, and between the power supply input and protective earth terminal, and 50 Hz, 3.0 kVAC is applied between the power supply input and I/O terminal for 1 minute.
Temperature Rise After rated continuous operation at normal ambient temperature and humidity, the temperature rise of the motor winding measured by the thermocouple method is 60 °C max. and that of the motor case surface is 50 °C max. *1
Operating Environment Ambient Temperature 0∼+40 °C (Non-freezing)
Ambient Humidity 85 % max. (Non-condensing)
Altitude Less than 1000 m above sea level
Atmosphere Cannot be used in special environments such as corrosive gas, no dust, radioactive materials, magnetic fields, or vacuums
Vibration Not subject to continuous vibration or excessive shock In conformance with JIS C 60068-2-6, "Sine-wave vibration test method"
Frequency Range: 10~55 Hz, Half Amplitude: 0.15 mm, Sweep Direction: 3 directions (X, Y, Z), Number of Sweeps: 20 times
Storage Conditions*2 Ambient Temperature -25 °C~+70 °C (non-freezing)
Ambient Humidity 85 % max. (Non-condensing)
Altitude Up to 3000 m above sea level
Thermal Class 120 (E)
Degree of Protection IP20
*1
Attach round shaft types to a heat sink (Material: aluminum) of one of the following sizes to maintain a motor case surface temperature of 90 °C max.
200 × 200 mm, 5 mm thickness
*2
The value for storage condition applies to short periods such as the period during transport.
close