Electromagnetic Brake Motors KII Series (New standard)

2RK6A-UCM

2RK6A-UCM

Motor

  This product is currently no longer available for sale
Product Classification Product Name List Price List Price Shipping Date
Motor 2RK6A-UCM SGD 157 USD 126 Discontinued Product
(31.3.2024 discontinued)

Included

  • Motor, Capacitor, Capacitor Cap, Operating Manual

Specifications

Characteristics

Starting and Braking Characteristics (Reference values)
Starting and Braking Characteristics (Reference values)

Starting and Braking Characteristics (Reference values)

Dimensions

Motor
Motor

Motor

Capacitor
Capacitor

Capacitor

Data Download

Other Specifications

General Specifications

Item Specifications
Insulation Resistance After rated operation at normal ambient temperature and humidity, the measurement between the coils and the case is 100 MΩ min. using a 500 VDC megger.
Dielectric Strength After continuous rated operation at normal ambient temperature and humidity, no abnormalities were observed even with an application of 1.5 kV at 50 Hz or 60 Hz between the coils and the case for 1 minute.
Temperature Rise A gearhead or equivalent heat sink*1 is connected to the motor and the winding temperature rise is measured at 80 °C max. using the resistance change method after continuous rated operation under normal ambient temperature and humidity. (Three-Phase type is 70 °C max.)
Thermal Class 130 (B)
Overheat Protective Device The 6 W type is impedance protected
Other types: Built-in thermal protector (Automatic return type) Open: 130 ± 5 °C, Return: 85 ± 20 °C
Operating Ambient Temperature Three-phase 200 V, Single-phase 100 V, Single-phase 200 V: -10~+50 °C (Non-freezing)
Other voltages: -10~+40 °C (Non-freezing)
For gearhead gear ratios 2 or 3 the lower temperature limit is 0 °C.
Operating Ambient Humidity 85 % max. (Non-condensing)
Degree of Protection
Terminal box type:
IP66*2 (Excluding mounting surface of the round shaft type)
IP20 (60 W, 90 W)
Lead wire type:
IP20 (6 W, 15 W, 25 W)
Cable Type:
IP40 (40 W)
IP20 (60 W, 90 W)
*1
Heat Sink Size (Material: Aluminum)
Motor Type
(Output)
Size
(mm)
Thickness
(mm)
6 W Type 115 x 115 5
15 W Type 125 x 125
25 W Type 135 x 135
40 W Type 165 x 165
60 W, 90 W Type 200 x 200
*2
For Materials and Surface Treatments
Type Output Power Materials Surface Treatment
Parallel shaft Combination
Round Shaft
40 W Motor case, terminal box: Aluminum
Output shaft: S45C
Screws: Stainless steel (externally facing screws only)
Motor case,
terminal box: Painted (excluding installation surface)

Permissible Radial Load and Permissible Axial Load of Round Shaft

Product Name Permissible Radial Load N Permissible Axial Load
Distance From the End of the Motor Output Shaft
10 mm 20 mm
2IK6
2RK6
50 110 Half of the motor mass or less*
3IK15
3RK15
40 60
4IK25
4RK25
90 140
5IK40
5RK40
140 200
5IK60
5IK90
5RK60
5RK90
240 270
  • * Avoid applying axial loads as much as possible.
    If an axial load is unavoidable, keep it at half or less of the motor mass.