Other Specifications

General Specifications

Item Specifications
Insulation Resistance 100 MΩ or more when a 500 VDC megger is applied between the windings and the case after 30 minutes continuous operation under normal ambient temperature and humidity.
Dielectric Strength Sufficient to withstand 1.5 kVAC at 50 Hz or 60 Hz applied between the motor windings and the case for 1 minute after 30 minutes continuous operation under normal ambient temperature and humidity.
Temperature Rise After 30 minutes of continuous operation at normal ambient temperature and humidity with the gearhead or equivalent heat sink* connected to the motor, the winding temperature rise value measured using the resistance change method will be 80 °C max.
Thermal Class 130 (B)
Overheat Protective Device The 6 W type is impedance protected
Other types: Built-in thermal protector (Automatic return type) Open: 130 ± 5 °C, Return: 85 ± 20 °C
Operating Ambient Temperature Single-Phase 100 V, Single-Phase 200 V: -10~+50 °C (Non-freezing)
Other voltages: -10~+40 °C (Non-freezing)
For gearhead gear ratios 2 or 3 the lower temperature limit is 0 °C.
Operating Ambient Humidity 85 % max. (Non-condensing)
Degree of Protection
Terminal box type:
IP40 (25 W, 40 W)
IP20 (60 W, 90 W)
Lead wire type:
IP20
  • * Heat Sink Size (Material: Aluminum)
Motor Type (Output power) Size (mm) Thickness (mm)
6 W Type 115 x 115 5
15 W Type 125 x 125
25 W Type 135 x 135
40 W Type 165 x 165
60 W, 90 W Type 200 x 200

Permissible Radial Load and Permissible Axial Load of Round Shaft

Product Name Permissible Radial Load N Permissible Axial Load
Distance From the End of the Motor Output Shaft
10 mm 20 mm
2IK6
2RK6
50 110 Half of the motor mass or less*
3IK15
3RK15
40 60
4IK25
4RK25
90 140
5IK40
5RK40
140 200
5IK60
5IK90
5RK60
5RK90
240 270
  • * Avoid applying axial loads as much as possible.
    If an axial load is unavoidable, keep it at half or less of the motor mass.