Induction Motors World K Series (GU type, former type)
2IK6A-CWJ
Motor
Product Classification | Product Name | List Price | List Price | Shipping Date |
---|---|---|---|---|
Motor | 2IK6A-CWJ | - | - | Discontinued Product (1.4.2015 discontinued) |
Included
- Motor, Capacitor, Capacitor Cap, Operating Manual
Specifications
Data Download
Other Specifications
General Specifications
Item | Specifications |
---|---|
Insulation Resistance | After rated operation at normal ambient temperature and humidity, the measurement between the coils and the case is 100 MΩ min. using a 500 VDC megger. |
Dielectric Strength | After continuous rated operation at normal ambient temperature and humidity, no abnormalities were observed even with an application of 1.5 kV(three-phase 380/400 VAC is 2.0 kVAC) at 50 Hz or 60 Hz between the coils and the case for 1 minute. |
Temperature Rise | A gearhead or equivalent heat sink*1 is connected for rated operation at normal ambient temperature and humidity, the measurement value of the winding temperature rise is 80 °C max. (70 °C max. for a three-phase 6 W type) using the resistance change method. |
Thermal Class | 130(B) |
Overheat Protective Device | The 6 W type is impedance protected Other types: Built-in thermal protector (Automatic return type) Open: 130 ± 5 °C, Return: 82 ± 15 °C |
Operating Ambient Temperature | Single-phase 100 V, single-phase 200 V, three-phase 200 V: -10~+50 °C (Non-freezing) Other voltages: -10~+40 °C (Non-freezing) |
Operating Ambient Humidity | 85 % max. (Non-condensing) |
Degree of Protection |
Lead Wire Type:
IP20
Terminal Box Type:
6 W (Excluding mounting surface of the round shaft type.) IP54*2
25 W~90 W round shaft type IP40 25 W, 40 W pinion shaft type IP54 60 W, 90 W pinion shaft type IP44 |
- *1
- Refer to the table below for the size of the heat sink. (Material: aluminum)
- *2
- Only when using a φ8.5 cable. (Otherwise, IP40)
Motor Type (Output power) | Size (mm) | Thickness (mm) |
---|---|---|
6 W Type | 115 x 115 | 5 |
15 W Type | 125 x 125 | |
25 W Type | 135 x 135 | |
40 W Type | 165 x 165 | |
60 W, 90 W Type | 200 x 200 |
Permissible Radial Load and Permissible Axial Load of Round Shaft Type
Permissible Radial Load
Motor | Permissible Radial Load N | ||
---|---|---|---|
Frame Size □ (mm) | Output Shaft Diameter φ (mm) | From Shaft End 10 mm |
From Shaft End 20 mm |
42 | 5 | 40 | - |
60 | 6 | 50 | 110 |
70 | 6 | 40 | 60 |
80 | 8 | 90 | 140 |
90 | 10 | 140 | 200 |
12 | 240 | 270 |
Permissible Axial Load
Avoid axial load as much as possible. If an axial load is unavoidable, keep it at half or less of the motor mass.
System Configuration
Cables and Accessories
You can add it to "Quote and Purchase at the Online Shop" by checking the product name column.