Induction Motors

0IK3A-BW3U

0IK3A-BW3U

Motor

Product Classification Product Name List Price List Price Shipping Date
Motor 0IK3A-BW3U SGD 90 USD 72 16 Working Days

Included

  • Motor : Capacitor, Capacitor Cap

Specifications

Dimensions

Motor
Motor

Motor

Capacitor
Capacitor

Capacitor

Data Download

Other Specifications

General Specifications

1 W, 3 W Types

Item Specifications
Insulation Resistance After rated operation at normal ambient temperature and humidity, the measurement between the coils and the case is 100 MΩ min. using a 500 VDC megger.
Dielectric Strength After continuous rated operation at normal ambient temperature and humidity, no abnormalities were observed even with an application of 1.5 kV at 50 Hz or 60 Hz between the coils and the case for 1 minute.
Temperature Rise A gearhead or equivalent heat sink* connected to the motor and the winding temperature rise is measured at 75 °C max. using the resistance change method after continuous rated operation under normal ambient temperature and humidity.
Thermal Class UL/CSA Standards: 105 (A), EN Standards: 120 (E)
Overheat Protective Device Impedance Protected
Operating Ambient Temperature -10~+40 °C (Non-freezing)
Operating Ambient Humidity 85 % max. (Non-condensing)
Degree of Protection IP20

6 W~90 W Type, 2-Pole, High-Speed Type

Item Specifications
Insulation Resistance After rated operation at normal ambient temperature and humidity, the measurement between the coils and the case is 100 MΩ min. using a 500 VDC megger.
Dielectric Strength After continuous rated operation at normal ambient temperature and humidity, no abnormalities were observed even with an application of 1.5 kV(three-phase 380/400/415 VAC is 2.0 kVAC) at 50 Hz or 60 Hz between the coils and the case for 1 minute.
Temperature Rise A gearhead or equivalent heat sink* is connected to the motor and the winding temperature rise is measured at 80 °C max. using the resistance change method after continuous rated operation under normal ambient temperature and humidity. (Three-Phase type is 70 °C max.)
Thermal Class 130(B)
Overheat Protective Device The 6 W type is impedance protected
Other types: Built-in thermal protector (Automatic return type) Open: 130 ± 5 °C, Return: 85 ± 20 °C
Operating Ambient Temperature Single-phase 100 V, single-phase 200 V, three-phase 200 V: -10~+50 °C (Non-freezing)
Other voltages: -10~+40 °C (Non-freezing)
Operating Ambient Humidity 85 % max. (Non-condensing)
Degree of Protection
Lead Wire Type:
IP20
Terminal Box Type:
6 W IP65 (excluding mounting surface)
25 W, 40 W, 60 W, 90 W, 150 W IP54 (excluding mounting surface)
  • *Heat Sink Size (Material: Aluminum)
Motor Type (Output power) Size (mm) Thickness (mm)
1 W, 3 W Type 80 x 80 5
6 W Type 115 x 115
15 W Type 125 x 125
25 W Type (2-Pole, High-Speed 4IK40 Type,
4IK60 Type)
135 x 135
40 W Type (2-Pole, High-Speed 5IK60 Type) 165 x 165
60 W, 90 W, 150 W Types 200 x 200

Permissible Radial Load and Permissible Axial Load of Round Shaft Type

Permissible Radial Load

Motor Permissible Radial Load N
Frame Size □ (mm) Output Shaft Diameter φ (mm) From Shaft End
10 mm
From Shaft End
20 mm
42 5 40 -
60 6 50 110
70 6 40 60
80 8 90 140
90 10 140 200
12 240 270

Permissible Axial Load

Avoid axial load as much as possible. If an axial load is unavoidable, keep it at half or less of the motor mass.

Radial Load and Axial Load

Standards

Regulations and Standards Materials

Documents about compliance with regulations and standards can be downloaded from the "Data Download" tab on the product details page.
(The types of files available for download vary by product.)

Explanations of the Global Laws, Regulations and Standards can be found here.

Information about our compliance with safety standards for each of our product models can be found here.

Hazardous Substances

The product does not contain any substances (10 substances) exceeding the regulation values of the RoHS Directive (2011/65/EU, 2015/863/EU).

System Configuration

System Configuration

Related Products

Brake Pack

Products Features
SB50W Series
SB50W Series
Features

This is a brake pack that enables instantaneous stopping, bidirectional rotation, and brake control of the motor, all in 1 unit.
 
This brake pack can increase the safety of equipment through the thermal protector open detection function.
 
In addition, alarm resetting by external signals is now possible, making it easier to use.
 

  • Supports Wide Voltage Range (100-230 VAC)
  • 48 mm × 48 mm DIN size
  • Conforms to Safety Standards
  • Compatible with 1 W~90 W Motors
  • Can Switch Sink/Source Logic

Cables and Accessories

You can add it to "Quote and Purchase at the Online Shop" by checking the product name column.

close
close
close