Specifications
Characteristics
Data Download
Other Specifications
General Specifications
World K Series 3 W, 6 W, 10 W, 20 W
Item | Specifications |
---|---|
Insulation Resistance | After rated operation at normal ambient temperature and humidity, the measurement between the coils and the case is 100 MΩ min. using a 500 VDC megger. |
Dielectric Strength | No abnormality is observed even with an application of 1.5 kVAC at 50 Hz between the coils and the case for 1 minute after rated operation at normal ambient temperature and humidity. |
Temperature Rise | A gearhead or equivalent heat sink* connected to the motor and the winding temperature rise is measured at 80 °C max. using the resistance change method after continuous rated operation under normal ambient temperature and humidity. |
Thermal Class | 130 (B) |
Overheat Protective Device | Built-in thermal protector (automatic return type) Open: 130 ±5 °C, Return: 85 ±20 °C |
Operating Ambient Temperature | Single-phase 50 V, single-phase 100 V, single-phase 200 VAC: -10~+50 °C (non-freezing) Single-phase 60 V, single-phase 110 V, single-phase 115 VAC, single-phase 220 V, single-phase 230 V: -10~+40 °C (non-freezing) |
Operating Ambient Humidity | 85 % max. (non-condensing) |
Degree of Protection | IP20 |
- *Heat Sink Size (Material: Aluminum)
Motor Type | Size (mm) | Thickness (mm) |
---|---|---|
3 W type | 115 × 115 | 5 |
6 W type | 125 × 125 | |
10 W type | 135 × 135 | |
20 W type | 165 × 165 |
K Series 40 W
Item | Specifications |
---|---|
Insulation Resistance | After rated operation at normal ambient temperature and humidity, the measurement between the coils and the case is 100 MΩ min. using a 500 VDC megger. |
Dielectric Strength | No abnormality is observed even with an application of 1.5 kVAC at 50 Hz between the coils and the case for 1 minute after rated operation at normal ambient temperature and humidity. |
Temperature Rise | After rated operation at normal ambient temperature and humidity, the measurement value of the motor surface temperature rise is 45 °C max. using the thermometer method. |
Thermal Class | 120 (E) |
Operating Ambient Temperature | -10~+50 °C (non-freezing) |
Operating Ambient Humidity | 85 % max. (Non-condensing) |
Standards
Regulations and Standards Materials
Documents about compliance with regulations and standards can be downloaded from the "Data Download" tab on the product details page.
(The types of files available for download vary by product.)
Explanations of the Global Laws, Regulations and Standards can be found here.
Information about our compliance with safety standards for each of our product models can be found here.
Hazardous Substances
The product does not contain any substances (10 substances) exceeding the regulation values of the RoHS Directive (2011/65/EU, 2015/863/EU).